ANTEL STR-1100 NOTES: This unit has three NAMS. The ESN prefix is 175 decimal & AF hex. ANTEL: 516-273-6939 NAM programing: 1. Turn power on. 2. Enter M (mute) 310 #. Step 01 (security code) will be displayed, press RCL to advance to the ESN display. 3. The up arrow key is used to store and increment each item. 4. The END key is used to complete and exit programing mode. PROGRAMING DATA: STEP# #OF DIGITS/RANGE DISPLAY DESCRIPTION 01 2567252 ONLY SEC CODE SECURITY CODE 02 UN CHANGEABLE HEX HEX ESN 03 UN CHANGEABLE DEC DECIMAL ESN 04 1, 2 OR 3 NAM SELECT 05 0 OR 1 PROG EXIST ENTER "1" TO PROCEED 06 10 DIGITS TEL NO AREA CODE & TEL NUMBER 07 00000 - 32767 SYSID SYSTEM ID 08 0 OR 1 LOCAL LOCAL USE MARK 09 0 OR 1 MIN MARK MIN MARK 10 0333 OR 0334 IPCH INITIAL PAGING CHANNEL 11 2 DIGITS ACCOLC ACCESS OVERLOAD CLASS 12 0 OR 1 PRESYS PREFERRED SYSTEM 13 2 DIGITS GIM GROUP ID (10 IN USA) 14 4 DIGITS LOCK LOCK CODE 15 0 OR 1 END TO END DTMF SIGNALLING 16 0 OR 1 A/B ALLOW USER A/B SELECT 17 0 OR 1 AREA ? SET TO "1" 18 0 OR 1 DTX VOX MODE 19 STO OR CLR PRESS STO TO ACCEPT OR CLR TO ABORT.