CELLQUEST



NOTES:  This is a single NAM unit.

        The ESN prefix is 174 decimal & AE hex.

        Shintom:  213-328-7200





NAM PROGRAMING:



1.  Turn power on.



2.  If not locked press FUNC 5 to lock.



3.  Enter FUNC # 6 2 6 # FUNC.  (626 SPELLS NAM)



4.  The SEND key stores and increments each step.



5.  You can jump to any entry by pressing END STEP# SEND.



6.  At any time press END FUNC END to complete and exit programing.



7.  The first two (unnumbered) steps below are not strictly programing

    data, and can not be altered, but are shown for clarity.



PROGRAMING DATA:



STEP#    #OF DIGITS/RANGE    DESCRIPTION



         CAN NOT BE CHANGED  MODEL NUMBER & SOFTWARE VERSION

         CAN NOT BE CHANGED  ESN IN HEX

01       3 DIGITS            AREA CODE

02       7 DIGITS            PHONE NUMBER

03       00000 - 32767       SYSTEM ID

04       2 DIGITS            ACCESS OVERLOAD CLASS

05       2 DIGITS            GROUP ID (10 IN USA)

06       0 OR 1              LOCAL USE MARK

07       0 OR 1              MIN MARK

08       3 DIGITS            LOCK CODE

09       0 OR 1              AUTO LOCK

10       3 DIGITS            CALL RESTRICTION CODE (DEFAULTS TO LOCK CODE)

11       2 DIGITS            CALL COUNTER RESET CODE (DEFAULTS TO FIRST TWO

                             DIGITS OF LOCK CODE)

12       0 OR 1              HANDS FREE

13       0 OR 1              HORN ALERT

14       0 TO 3              HORN ALERT TURN OFF DELAY (0 = 2 hrs, 1 = 4 hrs,

                             2 = 8 hrs, 3 = no turn off)

15       2 DIGITS            TOTAL AIRTIME RESET CODE (DEFAULTS TO FIRST TWO

                             DIGITS OF LOCK CODE)



LOCK: F5, UNLOCK: 3 DIGIT CODE



SYSTEM SELECT: F7 = A ONLY, F8 = B ONLY (F7 OR F8 AGAIN WILL TOGGLE BACK TO

PREF/NON PREF)