                 CMTELECOM AR 3800 mobile/transportable

-------------------------------------------------------------------------------

                NAM Type:  EEPROM

            Manufacturer:  CMTELECOM

          ESN Prefix DEC:  153

                     HEX:  99

ESN, Serial Number Match:  yes



    Programming Sequence:

                           Power ON

                           Lock Phone: FUNC + 1 + 1 (press 1 until "F-Lock"

                            displays) + SND

          Enter Password:  * + 5965 ("Conf 3800" will display, else enter

                            Password * + 0188)

                           Press VOL UP or DOWN keys to increment steps

                           RCL + 2 digit step # to reach specific parameters

                           SND must be pressed to save info after each step

                           To store complete NAM info press END



     Step            # of digits

      1 Mobile Number 1:  10    XXX-XXX-XXXX + SND + VOL UP

          2 System ID 1:  5     XXXXX + SND + VOL UP

    3 Init. paging ch 1:  3     333 or 334 + SND + VOL UP

    4 Access Overload 1:  2     XX + SND + VOL UP

           5 Group ID 1:  2     XX + SND + VOL UP

          6 Local Use 1:  1    1(SND to toggle) + VOL UP

      7 System Select 1:  1     0 = 0 + SND + VOL UP

                                1 = BA + SND + VOL UP

                                2 = A only + SND + VOL UP

                                3 = B only + SND + VOL UP

                                4 = Home + SND + VOL UP

         8,9 Not Used  (VOL UP)

     10 Mobile Number 2:  10    XXX-XXX-XXXX + SND + VOL UP

         11 System ID 2:  5     XXXXX + SND + VOL UP

  12 Init pagin Channel:  3     333 or 334 + SND + VOL UP

   13 Access Overload 2:  2     XX + SND + VOL UP

          14 Group ID 2:  2     XX + SND + VOL UP

         15 Local use 2:  1     1 (SND to toggle) + VOL UP

     16 System Select 2:  1     0 = AB + SND + VOL UP

                                1 = BA + SND + VOL UP

                                2 = A Only + SND + VOL UP

                                3 = B Only + SND + VOL UP

                                4 = Home + SND + VOL UP

          17 Future Use:  1     0 + SND + VOL UP

          18 Power Save:  1     0(Dis) or 1(Enable) + SND + VOL UP

           19 System ID:  5     XXXXX + SND + VOL UP

       20 Prog Password:  5     Leave at Factory Set Number + VOL UP



             Horn Alert:  FUNC + 4 + SND

        New Unlock Code:  NAM

         System Seltect:  FUNC + (ALPHA to scroll)

                          PrefA AB

                          PrefB BA

                          Only A

                          Only B

                          Only H Home



SND to enter selection